Quote request

0 products on your memo list

0

Downloads

Data sheets, CAD and more

Type series FZEC / FZZC / FZDC / FZVC / FZFC / FZSC

FZEC / FZZC / FZDC / FZVC / FZFC / FZSC
14
/fileadmin/_processed_/csm_T100_FZECQU600x65_a_b9bafe2475.png /fileadmin/user_upload/Product_Database/Bilder/T100_FZECQU600x65_a.png
/fileadmin/_processed_/csm_T100_FZECQU600x65_detail_137270539b.png /fileadmin/user_upload/Product_Database/Bilder/T100_FZECQU600x65_detail.png
/fileadmin/_processed_/csm_T100_FZECU600x65_front_f83e4fb90f.png /fileadmin/user_upload/Product_Database/Bilder/T100_FZECU600x65_front.png

technical description

Cemented wirewound tubular fixed resistor in one- up to six-tube design, degree of protection IP20 if mounted on an appropriate surface, with sidepanels and perforated cover. Fixing parallel to mounting surface. With two connections wired on terminals in attached terminal box with PG16-cable gland.

special features

• version protected against access to hazardous parts
• connections at two-pole polyamide terminals G10/2 up to 60A
• for wall mounting or mounting on switch cabinets

example of use

An important application is the use as braking resistor for motor/generator drive of motors with frequency converters, where medium ratings are required.
Various applications derive from the compact construction form for wall mounting or mounting on a switch cabinet.

Options

• Version of low inductance by bifilar winding and therefore of low noise
• with cage clamp terminals 1,5/2,5/4mm²
• This type can be equipped with a 180° C temperature switch (TS) (incl. M12 cable gland) for temperature monitoring. This signal has to be considered by the customer e.g. by a warning or disconnection of the mains.
Warning: There will not be a disconnection of the resistor!
Type designation would be: FZ.CQ ...
• Contact rating of the signal contact:
- 2 A / 24 VDC (DC11)
- 2 A / 230 VAC (AC11)
• UL recogniton
You will find suggestions for the dimensioning of the resistor for continuous and short term load in the data sheet.

Picture
Product
Power dissipation
Ω value production range
Maximum operating voltage
Features
FZEC 200x65

T100
Tubular Fixed Resistors
300 W
4,7 Ohm - 27 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZEC 300x65

T100
Tubular Fixed Resistors
430 W
6,8 Ohm - 47 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZEC 400x65

T100
Tubular Fixed Resistors
600 W
10 Ohm - 68 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZEC 500x65

T100
Tubular Fixed Resistors
800 W
12 Ohm - 82 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZEC 600x65

T100
Tubular Fixed Resistors
1000 W
15 Ohm - 100 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZZC 300x65

T100
Tubular Fixed Resistors
860 W
3,9 Ohm - 82 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZZC 400x65

T100
Tubular Fixed Resistors
1,2 kW
5,6 Ohm - 120 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZZC 500x65

T100
Tubular Fixed Resistors
1,6 kW
6,8 Ohm - 150 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZZC 600x65

T100
Tubular Fixed Resistors
2 kW
8,2 Ohm - 180 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZDC 300x65

T100
Tubular Fixed Resistors
1,3 kW
2,7 Ohm - 82 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZDC 400x65

T100
Tubular Fixed Resistors
1,8 kW
3,3 Ohm - 120 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZDC 500x65

T100
Tubular Fixed Resistors
2,4 kW
3,9 Ohm - 150 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZDC 600x65

T100
Tubular Fixed Resistors
3 kW
5,6 Ohm - 180 kOhm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZVC 400x65

T100
Tubular Fixed Resistors
2,4 kW
2,7 Ohm - 420 Ohm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZVC 500x65

T100
Tubular Fixed Resistors
3,2 kW
3,3 Ohm - 320 Ohm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZVC 600x65

T100
Tubular Fixed Resistors
4 kW
3,9 Ohm - 250 Ohm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZFC 400x65

T100
Tubular Fixed Resistors
3 kW
2,2 Ohm - 340 Ohm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZFC 500x65

T100
Tubular Fixed Resistors
4 kW
2,7 Ohm - 250 Ohm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZFC 600x65

T100
Tubular Fixed Resistors
5 kW
3,3 Ohm - 180 Ohm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZSC 400x65

T100
Tubular Fixed Resistors
3,6 kW
1,8 Ohm - 280 Ohm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZSC 500x65

T100
Tubular Fixed Resistors
4,8 kW
2,2 Ohm - 210 Ohm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant
FZSC 600x65

T100
Tubular Fixed Resistors
6 kW
2,7 Ohm - 170 Ohm
up to 3 x 500 VAC and derived DC voltages

UL-recognition (USA and Canada) availableCE ConformityRoHS / REACH compliant

Contact

FRIZLEN GmbH u. Co KG.
Gottlieb-Daimler-Straße 61
71711 Murr
Germany

  E-mail
 +49 (0) 71 44 81 00-0
 +49 (0) 71 44 20 76 30